Injection molding machine common fault treatment method

2024-10-07 09:33:09 Injection molding machine

First, the oil pump motor and oil pump start, but not pressure.

1. The proportional valve on the oil pump is loose or the coil is burned - check whether the proportional pressure valve is energized.

2. Impurities block the oil port of the proportional pressure valve on the oil pump -- remove the proportional pressure valve to 

remove impurities.

3. The pressure oil is unclean, the debris accumulates on the surface of the oil filter, preventing the pressure oil from entering the 

pump - clean the oil filter and replace the pressure oil.

4. Oil leakage inside the oil pump, caused by too long use, internal loss or pressure oil unclean damage - repair or replace the oil 

pump.

5. Oil spillage barrels, oil pipes and joints - eliminate leakage areas.

6. Oil business card printing dead - check whether the oil spool activity is normal.

injection mould


Second, the melting tube temperature can not be controlled

1. If the temperature cannot be controlled, check whether the contact of the electric heating contactor is sticky, and whether the wire of the thermocouple is loose or damaged.

2. If the temperature cannot rise, check whether the electric heating air switch in the electric box is off, whether the contactor and relay are drawn, whether there is voltage, whether the insurance is burned out, and whether the heating ring is burned out.

3. Check whether the thermometer is damaged.


Three, no mold locking

1. Whether the front opening safety door has been closed, whether the stopper of the safety door has been pressed and loosened 

by the safety door, and whether the wiring is loose or damaged.

2. The mode-locked solenoid coil may have moved inside the valve and stuck the spool -- clean or replace the mode-locked mold 

opening control valve.

3. Direction valve may be out of position - Clean the direction valve.

4. The thimble cannot be returned to reset -- check whether the thimble works normally.

5. Check whether the origin of the mode-locking and mode-opening electronic ruler of the computer controller has changed and 

whether the mode-locking position has terminated.

6. Check whether the pressure gauge works.

7. Press the mode-locking key to see whether the display displays mode-locking signals or other signals and alarms.

8. Check whether the position, speed and pressure of the mold lock are adjusted normally.

9. Check whether the clamping piston rod is broken.


Four, do not shoot glue

1. The coil of the injection solenoid system may have been burned, or there are foreign objects entering the direction valve, and the 

valve core is stuck to move - clean or replace the injection valve.

2. The pressure is too low -- adjust the pressure of the high jet glue.

3. The temperature of injection molding is too low - adjust the thermometer to increase the temperature to the required point, such 

as adjusting the thermometer still can not increase the temperature, check whether the electric heater and fuse are burned out

Or loose break, if broken, timely replacement.

4. The injection combination valve opening system connection is loose or poor contact - the combination switch wire connector is 

properly connected.


Fifth, the glue screw rotates, but the rubber material does not enter the barrel

1. The melt back pressure is too high, the back pressure valve is damaged or improperly adjusted -- adjust or replace the melt back 

pressure valve.

2. Insufficient water transport, so that the temperature is too high, so that the rubber particles into the screw is blocked - adjust the 

water transport, take out the bonded rubber block. See if the water conveyor is blocked or has no cooling water

3. There is no material in the bucket - add material.

4. Whether the melt tube temperature is too high.


Six. The shooting platform does not move

1. The moving limit travel switch of the shooting platform is pressed by the adjusting ram - adjust.

2. The coil of the shooting platform moving solenoid valve may be burned or there are foreign objects entering the direction valve 

stuck in the spool to move - clean or replace the solenoid valve.

3. Check the forward speed of the shooting platform and whether the pressure is improperly adjusted.

4. Check the 1/0 board, the direction valve output voltage (DC+24V) is normal, if not normal, check the corresponding output 

transistor or relay is damaged.

5. Press the station key to check whether the computer display displays the signal in front of the station, or other signals and alarms.

6. Check whether the pressure gauge works.

injection mould


Home
Product
News
Contact
主站蜘蛛池模板: 亚洲精品理论电影在线观看| 日本护士吞精囗交gif| 国产精品久久久久久久久软件| 免费观看交性大片| 玩弄丰满少妇视频| 国产成人高清精品免费软件| 国产免费拔擦拔擦8x高清在线人| 久久中文字幕人妻丝袜系列| 日本精品巨爆乳无码大乳巨| 免费人成网ww555kkk在线| 亚洲日韩一区精品射精| 亚洲色av天天天天天天| 欧美国产亚洲日韩在线二区| 丝袜美腿丝袜亚洲综合| 久久www免费人咸_看片| 久久99九九精品久久久久蜜桃| 精品国产污污免费网站| 精品国产成人国产在线视| 天堂资源在线www中文| 日韩av中文无码影院| 国产精品久久人妻无码| 超清制服丝袜无码av福利网| 午夜福利片1000无码免费| 女人爽得直叫免费视频| 亚洲欧美日本中文字不卡| 中国老熟妇| 成人无遮挡18禁免费视频 | 天天鲁一鲁摸一摸爽一爽| 国产精品一区二区av片| 人人妻人人澡人人爽超污| 青草精品国产福利在线视频| 性色av一区二区三区夜夜嗨| 国产激情无码一区二区app| 亚洲亚洲人成综合网络| 成人无码一区二区三区网站| 成人啪啪高潮不断观看| 无码少妇一区二区浪潮av| 麻花传媒mv在线观看| 国产在线精品一区二区三区不卡 | 中文av伊人av无码av狼人| 在线亚洲午夜理论av大片|